dc.description.abstractNew requirements for a better sustainable energy policy around the world is easy to observe, many projects in sustainable energy are developed wherein the academia works together the authorities and commercial firms such as electrical grid utilities. In distribution transformers one of the suggested solutions is to replace mineral oils used as dielectric and coolant for natural ester fluids, they provide improved technical properties making them a safe substitute of mineral oil. Natural esters are based on clean technology in order to guarantee requirements from utilities. The main goal of the present paper is to present a technical-economic analysis obtained from five years of applications of oil-immersed transformers using natural ester fluids in Colombia. The methodology considers forty-four oil-immersed distribution Transformers, a half use mineral oil and the other side use natural ester, operating under the same load regime. Results evidenced the feasibility of implementing this technology because the costs are very similar and the reduction of risks and environmental impact is considerable.eng
dc.language.isoengeng
dc.publisherAIP Publishingeng
dc.rightsinfo:eu-repo/semantics/restricciónedAccessspa
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceAIP Conference Proceedingseng
dc.sourceVol. 2123 No. 1 (2019)spa
dc.source.urihttps://doi.org/10.1063/1.5116976eng
dc.subjectDistribution transformerseng
dc.subjectMineral Oileng
dc.subjectNatural ester fluidseng
dc.subjectSafety operation in power distribution systemeng
dc.titleNatural ester fluids applications in transformers as a sustainable dielectric and coolanteng
dc.typearticleeng
dcterms.referencesAb Ghani, S., Muhamad, N. A., Noorden, Z. A., Zainuddin, H., Abu Bakar, N., & Talib, M. A., "Methods for improving the workability of natural ester insulating oils in power transformer applications: A review". Electric Power Systems Research. 163, 655-667, (2018).eng
dcterms.referencesDelgado, F., Fernandez, I., Ortiz, F., Renedo, C., Ortiz, A., and Carcedo, J., "Thermal analysis of transformers insulation based on vegetable esters". In 33rd Electrical Insulation Conference, EIC 2015, pp. 606–609. (2015).eng
dcterms.referencesMcshane, P., "Vegetable-Oil-Based Dielectric Coolants. IEEE Industry" Applications Magazine, 8(3), 34–41. (2002).eng
dcterms.referencesRycroft, M., "Vegetable oil as insulating fluid for transformers". Energize, 37–40. (2014).eng
dcterms.referencesAsano, Roberto, and Stephane A. Page. "Reducing environmental impact and improving safety and performance of power transformers with natural ester dielectric insulating fluids." IEEE Transactions on Industry Applications 50 (1), 134-141. (2014)eng
dcterms.referencesCiuriuc, A., Vihacencu, M. S., Dumitran, L. M., and Notingher, P. V., "Comparative Study on Power Transformers Vegetable and Mineral Oil Ageing". 2012 International Conference on Applied and Theoretical Electricity (ICATE). IEEE, (2012).eng
dcterms.referencesSagastume Gutiérrez, A., Cabello Eras, J. J., Sousa Santos, V., Hernández Herrera, H., Hens, L., and Vandecasteele, C. "Electricity management in the production of lead-acid batteries: The industrial case of a production plant in Colombia". Journal of Cleaner Production, 198, 1443–1458. (2018).eng
dcterms.referencesCIGRE working group A2-35., "Experiences in Service with New Insulating Liquids". United Kingdom: Zhongdong Wang (UK). (2010).eng
dcterms.referencesEPA., OPPTS 835.3100. "Aerobic Aquatic Biodegradation. Fate, Transport and Transformation" Test Guidelines. (Thomas A. Edison Technical Center, Ed.). Franksville (USA): Cooper Power Systems. (1998).eng
dcterms.referencesHopkinson, P., "Progress Report On Natural Esters For Distribution And Power Transformers". IEEE Power and Energy Society General Meeting IEEE, (2009).eng
dcterms.referencesLi, J., Zhang, Z., Grzybowski, S., and Liu, Y., "Characteristics of Moisture Diffusion in Vegetable Oil-paper Insulation", EEE Transactions on Dielectrics and Electrical Insulation 19 (5), 1650–1656. (2012)eng
dcterms.referencesBashi, S. M., Abdullahi, U. U., Yunus, R., and Nordin, A., "Use of Natural Vegetable Oils as Alternative Dielectric Transformer Coolants". Journal of the Institution of Engineers, Malaysia, 67(2), 4–9. (2006).eng
dcterms.referencesMurphy, J. R., Member, S., and Graham, J., "Distribution Utility Experience with Natural Ester Dielectric Coolants", 2009 IEEE Power & Energy Society General Meeting. IEEE, (2009).eng
dcterms.referencesMcshane, C. P., "Natural and Synthetic Ester Dielectric Fluids : Their Relative Environmental , Fire Safety , and Electrical Performance". In 1999 IEEE Industrial and Commercial Power Systems Technical Conference pp. 1-8. (1999).eng
dcterms.referencesNavas, D., Cadavid-Ramírez, H., and Echeverry-Ibarra, D. F. "Aplicación del aceite dieléctrico de origen vegetal en transformadores eléctricos". Ingeniería y Universidad, 16(1), 201–223. (2012),spa
dcterms.referencesRebolledo, L. and, Guissela. A., "Evaluación de la viabilidad técnica y económica de la utilización del aceite dieléctrico vegetal como sustituyente del aceite dieléctrico mineral en transformadores de distribución nuevos y usados en las empresas municipales de Cali. BS thesis,Universidad Autónoma de Occidente.spa
dcterms.referencesSilva-Ortega, J. I., Candelo-Becerra, J. E., Umaña-Ibañez, S. F., Mejia-Taboada, M. A., and Palacio-Bonill, A. R., "Power Distribution Transformers using Natural Ester Fluids as Dielectric and Coolant". Inge Cuc, 12(2), 79–85. (2016).eng
dcterms.referencesB Tokunaga, Junko, et al. "Palm fatty acid ester as biodegradable dielectric fluid in transformers: a review." IEEE Electrical Insulation Magazine 35.2 34-46. (2019):eng
dcterms.referencesIEC, IEC 62770. Fluids for electrotechnical applications – Unused natural esters for transformers and similar electrical equipment. Geneva, Switzerland, 2013, p. 38.eng
dcterms.referencesASTM. D6871-03: Standard Specification for Natural (Vegetable Oil) Ester Fluids Used in Electrical Apparatus, 10ASTM 14–16, 2003.eng
dcterms.referencesArief, Y. Z., Ahmad, M. H., Lau, K. Y., and Oil, A. T., "A Comparative Study on the Effect of Electrical Ageing on Electrical Properties of Palm Fatty Acid Ester ( PFAE ) and FR3 as Dielectric Materials", IEEE International Conference on Power and Energy (PECon). IEEE,128–133.2014.eng
dcterms.referencesCargill. EnvirotempTM FR3TM Fluid. R2020 Reference Data. (2013).eng
dcterms.referencesGlobalTox International Consultants. Final Report: Acute Trout Toxicity Testing for Two Envirotemp FR3 Formulations, (2). (1999).eng
dcterms.referencesAluyor, E. O., Obahiagbon, K. O., and Ori-jesu, M., "Biodegradation of vegetable oils : A review". Scientific Research and Essays ,4(6), 543–548. (2009).eng
dcterms.referencesFofana, I., 2013. "50 Years in the Development of Insulating Liquids", IEEE Electrical Insulation Magazine 29(5), 13-25, (2013).eng
dcterms.referencesBrettis. "Aceites Para Transformadores", Modulo 8. Retrieved from http://www.brettis.com/Tutorial/08Transformadores.pdf. (2013).eng
dcterms.referencesSingha, Santanu, et al. "Comparative aging characteristics between a high oleic natural ester dielectric liquid and mineral oil." IEEE Transactions on Dielectrics and Electrical Insulation 21.1 (2014): 149-158. Villardi, H. GD., Leal, M. F., Andrade, P. H. D. A., Fernando, L. P., and Salgado, A. M. "Study of the Production of Ethyl Esters of Soybean Industry Using Waste Acid with and without Catalyst". Chemical EngineeringTransactions, 57, 163–168. (2017).eng
dcterms.referencesChistyakov, A. V., Tsodikov, M. V., Zharova, P. A., Kriventsov, V. V., Corbetta, M., and Manenti, F. "The direct hydrodeoxygenation of vegetable oil over Pt-Sn/Al2O3 catalysts". Chemical Engineering Transactions, 57, 871–876. (2017).eng
dcterms.referencesCongreso de Colombia. Ley N° 1715 Del 13 De Mayo De 2014,2014, Colombia. Retrieved from http://www.upme.gov.co/Normatividad/Nacional/2014/LEY_1715_2014.pdfspa
dcterms.referencesUPME. Res. 0536 - 2012 2012, Colombia. Retrieved from http://www1.upme.gov.co/Documents/Normatividad/Resoluciones/RES._0563.pdf.eng
dcterms.referencesArfaoui, A., Polidori, G., Taiar, R., and Popa, C., "Infrared Thermography in Sports Activity". In Infrared Thermography, 141–168. (2012).eng
dcterms.referencesASTM. D3487-16: Standard Specification for Mineral Insulating Oil Used in Electrical Apparatus, 2016.eng


Ficheros en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

  • Artículos [1351]
    Artículos científicos evaluados por pares

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/restricciónedAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/restricciónedAccess